ICES-3240-GE

4 10/100/1000TX + 2 1000M SFP Industrial Managed Switch

  • Support SSH,SSL,RADIUS/TACACS+
  • Support Denial-of-Service (DOS) prevention.
  • IPV6 & IPV4 Based ACL
  • Built in 802.3az for power saving
  • Support SNMP V2c/V3
  • Support IPV6 Management
  • Loop protection prevents network attack and Loopback cable protection.
  • Support Advanced SNMP including QoS, IGMP V2 /V3 snooping and query

The ICES-3240-GE is an 4-port 10/100/1000BaseTX + 2-port 1000M SFP industrial switch. The advanced SNMP management features include QoS for 8 queues, 802.1q VLAN, 802.1v Protocol Based VLAN, IGMP V2/V3 snooping and query, MLD-Snooping, LLDP-MED, Loop protect prevents network attack and loopback cable protection, as well as SNTP and etc.

ICES-3240-GE builds all the important management features required in large network like, DHCP Client, 802.1X authentication, IGMP Query / Snooping, advanced QoS.

ICES-3240-GE provides a variety of advanced security features to safe guard your network. These security protection functions include 802.1X, RADIUS/TACACS+, HTTPS, SSL, Port Security, Storm Control, Denial-of-Service (DOS) Prevention, Dynamic ARP Inspection, IP Source Guard ,etc.

The ICES-3240-GE With the powerful ACL utility, administrator can restrict sensitive portions of the network from unauthorized users and guard against network attacks. ICES-3240-GE support MAC-based ACL, IPV4-based ACL and IPV6-based ACL.    

The ICES-3240-GE With built-in IEEE802.3az Energy Efficient Ethernet (EEE) feature and more innovative green feature, ICES-3240-GE can reduce energy consumption through many smart automatic detection, such as Link Down Power Saving, Cable Length Power Saving, No traffic or Small traffic Power Saving.

The ICES-3240-GE is the best to be used in municipal, city surveillance, automation, transportation, mining, heavy Industrial factory and other factory assembly lines where needs network management functionality. The -E model can be used in extreme environments with an operating temperature range of -30°C to 70°C.

  • RJ-45 Port Support Auto MDI/MDI-X Function
  • SFP slot supports 100/1000 Dual Mode with DDM for SFP diagnostic and monitoring(need to work with SFP with diagnostic function)
  • Back-plane (Switching Fabric): 20 Gbps
  • 8K MAC address table
  • IP-30 Protection with DIN rail and wall mount design
  • Redundant Power Design
  • IPv6 management
  • IEEE 802.1d Spanning Tree , IEEE 802.1w RSTP& IEEE 802.1s MSTP
  • IGMP with Snooping and Query mode for Multi Media Application; MLD-Snooping for IPV6
  • Support IP multicast dynamic source learning for IP CAM and video.
  • Port Based VLAN, 802.1Q Tag VLAN, GVRP
  • Port Trunk with LACP
  • Supports IEEE 802.1ab LLDP , LLDP-MED , UDLD
  • Supports IEEE 802.1p CoS, 8 priority queues per port
  • Port base, Tag Base and Type of Service Priority
  • Supports Ingress Packet Filter and Egress Rate Limit
  • Supports Broadcast/Multicast Packet Filter Control
  • Port Mirror: Monitor traffic in switched networks
    • TX, RX, Both of TX and RX Packet
  • Security
    • Port Security: MAC address entries/Filter/MAC violation
    • RADIUS/TACACS+
    • Login Security: IEEE802.1X
    • HTTPS and SSL
    • Denial-of-Service(DOS)Prevention
    • Dynamic ARP Inspection,
    • IP Source Guard
    • Loop Protection: prevents network attack, loopback cable detection and Miss-wiring avoidance
  • SNMP Trap
    • Device cold start, Power status, Authentication failure, Port Link up/Link down.
  • Relay Alarm Output System Events
  • SNTP for time sync
  • TFTP Firmware Update & System Configure Restore/Backup
  • Factory reset bottom can restore all setting back to factory default and Watchdog design to automatically reboot switch under certain circumstances

Hardware Specification

IEEE Standards

IEEE802.3 10Base-T Ethernet

IEEE802.3u 100Base-TX

IEEE802.3ab 1000Base-T

IEEE802.3z Gigabit fiber

IEEE802.3x Flow Control and Back Pressure

IEEE802.3ad Port trunk with LACP

IEEE802.3af Power over Ethernet

IEEE802.1d Spanning Tree

IEEE802.1w Rapid Spanning Tree

IEEE802.1s Multiple Spanning Tree

IEEE802.1p Class of Service

IEEE802.1Q VLAN Tag

IEEE802.1x User Authentication (Radius)

IEEE802.1ab LLDP

IEEE802.3az Power Saving

Switch Architecture

Back-plane (Switching Fabric): 12Gbps

Transfer Rate

14,881pps for Ethernet port

148,810pps for Fast Ethernet port

1,488,100pps for Gigabit Fiber Ethernet port

MAC Address

8K MAC address table

Flash ROM

16Mbytes

DRAM

128Mbytes

Connectors

10/100/1000TX: 4 x ports RJ-45 with Auto MDI/MDI-X function

1000 SFP port: 2 x SFP

RS-232 connector: RJ-45 type

Network Cable

10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable

EIA/TIA-568 100-ohm (100m)

100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable

EIA/TIA-568 100-ohm (100m)

1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable

EIA/TIA-568 100-ohm (100m)

Optical Fiber

Distance:

Multi mode:

0 to 5 km, 1300 nm (50/125 μm, 800 MHz*km)

0 to 4 km, 1300 nm (62.5/125 μm, 500 MHz*km)

Single mode:

0 to 40 km, 1310 nm (9/125 μm, 3.5 PS/(nm*km))

0 to 80 km, 1550 nm (9/125 μm, 19 PS/(nm*km))

Min. TX Output:

Multi mode: -20 dBm

Single mode: 0 to 40 km, -5 dBm; 0 to 80 km, -5 dBm

Max. TX Output:

Multi mode: -14 dBm

Single mode: 0 to 40 km, 0 dBm; 0 to 80 km, 0 dBm

Sensitivity: -36 to -32 dBm(SM); -34 to -30(MM)

Protocol

CSMA/CD

LED

Per unit: Power 1 (Green), Power 2 (Green), Fault (Red), System alive (Green)

4 port 10/100/1000: Link/Activity (Green), Speed (Green)

SFP port: 2 x LNK/ACT(Green),

Power Supply

Ethernet Data input 12V~48VDC;  Redundant power connective removable terminal block for master and slave power;

Overload current protection

Present

Operating Humidity

5% ~ 95% (Non-condensing)

Operating Temperature

Wide Operating Temperature for E models:

-30°C~70°C / -22°F~158°F

Storage Temperature

-40°C~85°C / -40°F~185°F

Case Dimension

IP-30, 59.6 (W) x 105 (D) x 152 (H) mm

Weight

700 g

Fan Number

0

Installation

Wall mount or DIN-type cabinet install

MTBF

190288 hrs

EMI & EMS

FCC Class A

EN61000-4-2 (ESD),

EN61000-4-3 (RS),

EN61000-4-4 (EFT),

EN61000-4-5 (Surge),

EN61000-4-6 (CS),

EN61000-4-8,

EN61000-4-11

EN61000-6-2(EMS)

EN61000-6-4(EMI)

Stability Testing

IEC60068-2-31 (Drop off), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration)

Power Consumption

9.2 W (no PoE load) for Ethernet data at full load

4.8W for no Ethernet data load

Warranty

3 years

Software Specification

Management

SNMP v1 v2c, v3/ Web/Telnet/CLI

SNMP Agent

SNMP V1/V2c/V3

VLAN

Port Based VLAN

IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.)

GVRP (256 Groups)

Double Tag VLAN (Q in Q)

Port Trunk with LACP

LACP Port Trunk: 4 Trunk groups/Maximum 4 trunk members

LLDP

Supports LLDP to allow switch to advise its identification and capability on the LAN

LLDP-MED

Support LLDP-MED via IPv6.

UDLD

UDLD (Unidirectional Link Detection) is a private protocol to detect a uni-directional fiber link between two Ethernet switches in order to prevent a looped network. UDLD is often used in switched Ethernet networks where Spanning-Tree is required to block one or more ports to prevent a loop from forming.  

Spanning Tree

Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree; IEEE802.1s Multiple Spanning Tree

BPDU GUARD

Protect or BPDU spoofing.

IPV6 Management

Allow the user access by IPv4 or IPv6,And IPv6 supports the following features.

IPv4/IPv6 Dual Protocol Stack

Auto Configuration

IPv6 Neighbor Discovery

ICMPv6

SNMP over IPv6

HTTP/HTTPS over IPv6

TFTP over IPv6

Ping over IPv6

DHCPv6

Quality of Service

The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Different Service

Class of Service

Supports IEEE802.1p class of service, per port provides 4 priority queues

Port Security

Supports 100 entries of MAC address for static MAC and another 100 for MAC filter

Port Mirror

Supports 3 mirroring types: “RX, TX and Both packet”

IGMP

Supports IGMP snooping v1,v2

256 multicast groups and IGMP query

IP Security

Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder.

Login Security

Supports IEEE802.1X Authentication/RADIUS

Flow Control

Supports Flow Control for Full-duplex and Back Pressure for Half-duplex

System Log

Supports System log record and remote system log server

SNTP

Supports SNTP to synchronize system clock to Internet

Bandwidth Control

Support ingress packet filter and egress packet limit

The egress rate control supports all of packet type and the limit rates are 100K~102400Kbps(10/100), 100K~256000Kbps(1000)

Ingress filter packet type combination rules are

Broadcast/Multicast/Unknown Unicast packet,

Broadcast/Multicast packet, Broadcast packet only and all of packet. The packet filter rate can be set from 100K~102400Kbps(10/100), 100K~256000Kbps(1000)

Relay Alarm

Provides one relay output for port breakdown, power fail alarm.

Alarm Relay current carry ability: 1A @ DC24V

SNMP Trap

1. Cold start

2. Link down

3. Link up

4. Authorization fail

DHCP

Provides DHCP Client/ DHCP Server/ Port and IP Binding

DNS

Provide DNS client feature and support Primary and Secondary DNS server.

Firmware Update

Supports TFTP firmware update, TFTP backup and restore.

Factory reset & Watchdog design

Factory reset bottom can restore all setting back to factory default and Watchdog design to automatically reboot switch under certain circumstances

*Future Release

**Optional

  • ICES-3240-GE

4 10/100/1000TX + 2 1000M SFP Managed Industrial Switch; -30°C to 70°C

DIN Rail Power

AD1048-24FS

4VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C

(ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.)

AD1024-24F  24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C
(ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.)
AD1240-48S 

48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C

(ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)

AD1120-48F

48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C

(ambient, derating each output at 2.5% per degree from 50°C ~ 70°C)

Mini GBIC (SFP)

  • 8330-162 MINI GBIC 1000SX (LC/0.5km) Transceiver
  • 8330-163 MINI GBIC 1000SX2 (LC/2km) Transceiver
  • 8330-165 MINI GBIC 1000LX (LC/10km) Transceiver
  • 8340-0591 MINI GBIC 1000LHX (LC/40km) Transceiver
  • 8330-166 MINI GBIC 1000XD (LC/50km) Transceiver
  • 8330-169 MINI GBIC 1000XD (LC/60km) Transceiver
  • 8330-167 MINI GBIC 1000ZX (LC/80km) Transceiver
  • 8330-170 MINI GBIC 1000EZX (120km) Transceiver
  • 8330-168 MINI GBIC 1000T (100m) Transceiver
  • 8330-061 100Base LX 30KM, Single-mode, LC Transceiver
  • 8330-060 100Base FX 2KM, Multi-mode, LC Transceiver
  • 8330-188 LTSFP-1000BX-10KM Transceiver (WDM 1310)
  • 8330-189 LTSFP-1000BX-10KM Transceiver (WDM 1550)
  • 8330-186 LTSFP-1000BX-20KM Transceiver (WDM 1310)
  • 8330-187 LTSFP-1000BX-20KM Transceiver (WDM 1550)
  • 8330-180 LTSFP-1000BX-40KM Transceiver (WDM 1310)
  • 8330-182 LTSFP-1000BX-40KM Transceiver (WDM 1550)
  • 8330-181 LTSFP-1000BX-60KM Transceiver (WDM 1310)
  • 8330-183 LTSFP-1000BX-60KM Transceiver (WDM 1550)
  • 8330-184 LTSFP-1000BX-80KM Transceiver (WDM 1490)
  • 8330-185 LTSFP-1000BX-80KM Transceiver (WDM 1550)