ICES-3080-GE
8 10/100/1000TX Industrial Managed Switch
- Support SSH,SSL,RADIUS/TACACS+
- Support Denial-of-Service (DOS) prevention.
- IPV6 & IPV4 Based ACL
- Built in 802.3az for power saving
- Support SNMP V2c/V3
- Support IPV6 Management
- Loop protection prevents network attack and Loopback cable protection.
- Support Advanced SNMP including QoS, IGMP V2 /V3 snooping and query
The ICES-3080-GE is an 8-port 10/100/1000BaseTX industrial switch. The advanced SNMP management features include QoS for 8 queues, 802.1q VLAN, 802.1v Protocol Based VLAN, IGMP V2/V3 snooping and query, MLD-Snooping, LLDP-MED, Loop protect prevents network attack and loopback cable protection, as well as SNTP and etc.
ICES-3080-GE builds all the important management features required in large network like, DHCP Client, 802.1X authentication, IGMP Query / Snooping, advanced QoS.
ICES-3080-GE provides a variety of advanced security features to safe guard your network. These security protection functions include 802.1X, RADIUS/TACACS+, HTTPS, SSL, Port Security, Storm Control, Denial-of-Service (DOS) Prevention, Dynamic ARP Inspection, IP Source Guard ,etc.
The ICES-3080-GE With the powerful ACL utility, administrator can restrict sensitive portions of the network from unauthorized users and guard against network attacks. ICES-3080-GE support MAC-based ACL, IPV4-based ACL and IPV6-based ACL.
The ICES-3080-GE With built-in IEEE802.3az Energy Efficient Ethernet (EEE) feature and more innovative green feature, ICES-3080-GE can reduce energy consumption through many smart automatic detection, such as Link Down Power Saving, Cable Length Power Saving, No traffic or Small traffic Power Saving.
The ICES-3080-GE is the best to be used in municipal, city surveillance, automation, transportation, mining, heavy Industrial factory and other factory assembly lines where needs network management functionality. The -E model can be used in extreme environments with an operating temperature range of -30°C to 70°C.
- RJ-45 Port Support Auto MDI/MDI-X Function
- SFP slot supports 100/1000 Dual Mode with DDM for SFP diagnostic and monitoring(need to work with SFP with diagnostic function)
- Back-plane (Switching Fabric): 16 Gbps
- 8K MAC address table
- IP-30 Protection with DIN rail and wall mount design
- Redundant Power Design
- IPv6 management
- IEEE 802.1d Spanning Tree , IEEE 802.1w RSTP& IEEE 802.1s MSTP
- IGMP with Snooping and Query mode for Multi Media Application; MLD-Snooping for IPV6
- Support IP multicast dynamic source learning for IP CAM and video.
- Port Based VLAN, 802.1Q Tag VLAN, GVRP
- Port Trunk with LACP
- Supports IEEE 802.1ab LLDP , LLDP-MED , UDLD
- Supports IEEE 802.1p CoS, 8 priority queues per port
- Port base, Tag Base and Type of Service Priority
- Supports Ingress Packet Filter and Egress Rate Limit
- Supports Broadcast/Multicast Packet Filter Control
- Port Mirror: Monitor traffic in switched networks
- TX, RX, Both of TX and RX Packet
- Security
- Port Security: MAC address entries/Filter/MAC violation
- RADIUS/TACACS+
- Login Security: IEEE802.1X
- HTTPS and SSL
- Denial-of-Service(DOS)Prevention
- Dynamic ARP Inspection,
- IP Source Guard
- Loop Protection: prevents network attack, loopback cable detection and Miss-wiring avoidance
- SNMP Trap
- Device cold start, Power status, Authentication failure, Port Link up/Link down.
- Relay Alarm Output System Events
- SNTP for time sync
- TFTP Firmware Update & System Configure Restore/Backup
- Factory reset bottom can restore all setting back to factory default and Watchdog design to automatically reboot switch under certain circumstances
Hardware Specification |
|
IEEE Standards |
IEEE802.3 10Base-T Ethernet IEEE802.3u 100Base-TX IEEE802.3ab 1000Base-T IEEE802.3x Flow Control and Back Pressure IEEE802.3ad Port trunk with LACP IEEE802.1d Spanning Tree IEEE802.1w Rapid Spanning Tree IEEE802.1s Multiple Spanning Tree IEEE802.1p Class of Service IEEE802.1Q VLAN Tag IEEE802.1x User Authentication (Radius) IEEE802.1ab LLDP IEEE802.3az Power Saving |
Switch Architecture |
Back-plane (Switching Fabric): 16Gbps |
Transfer Rate |
14,881pps for Ethernet port 148,810pps for Fast Ethernet port 1,488,100pps for Gigabit Ethernet port |
MAC Address |
8K MAC address table |
Flash ROM |
16Mbytes |
DRAM |
128Mbytes |
Connectors |
10/100/1000TX: 8 x ports RJ-45 with Auto MDI/MDI-X function RS-232 connector: RJ-45 type |
Network Cable |
10Base-T: 2-pair UTP/STP Cat. 3, 4, 5/ 5E/ 6 cable EIA/TIA-568 100-ohm (100m) 100Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable EIA/TIA-568 100-ohm (100m) 1000Base-TX: 2-pair UTP/STP Cat. 5/ 5E/ 6 cable EIA/TIA-568 100-ohm (100m) |
Protocol |
CSMA/CD |
LED |
Per unit: Power 1 (Green), Power 2 (Green), Fault (Red), System alive (Green) 8 port 10/100/1000: Link/Activity (Green), Speed (Green) |
Power Supply |
Ethernet Data input 12V~48VDC; Redundant power connective removable terminal block for master and slave power; |
Overload current protection |
Present |
Operating Humidity |
5% ~ 95% (Non-condensing) |
Operating Temperature |
Standard: -10°C~60°C / 14°F~140°F Wide Operating Temperature for E models: -30°C~70°C / -22°F~158°F |
Storage Temperature |
-40°C~85°C / -40°F~185°F |
Case Dimension |
IP-30, 59.6 (W) x 105 (D) x 152 (H) mm |
Weight |
700 g |
Fan Number |
0 |
Installation |
Wall mount or DIN-type cabinet install |
MTBF |
190288 hrs |
EMI & EMS |
FCC Class A EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 EN61000-6-2(EMS) EN61000-6-4(EMI) |
Stability Testing |
IEC60068-2-31 (Drop off), IEC60068-2-27 (Shock), IEC60068-2-6 (Vibration) |
Power Consumption |
9.2 W (no PoE load) for Ethernet data at full load 4.8W for no Ethernet data load |
Warranty |
3 years |
Software Specification |
|
Management |
SNMP v1 v2c, v3/ Web/Telnet/CLI |
SNMP Agent |
SNMP V1/V2c/V3 |
VLAN |
Port Based VLAN IEEE 802.1Q Tag VLAN (256 entries)/ VLAN ID (Up to 4K, VLAN ID can be assigned from 1 to 4096.) GVRP (256 Groups) Double Tag VLAN (Q in Q) |
Port Trunk with LACP |
LACP Port Trunk: 4 Trunk groups/Maximum 4 trunk members |
LLDP |
Supports LLDP to allow switch to advise its identification and capability on the LAN |
LLDP-MED |
Support LLDP-MED via IPv6. |
UDLD |
UDLD (Unidirectional Link Detection) is a private protocol to detect a uni-directional fiber link between two Ethernet switches in order to prevent a looped network. UDLD is often used in switched Ethernet networks where Spanning-Tree is required to block one or more ports to prevent a loop from forming. |
Spanning Tree |
Supports IEEE802.1d Spanning Tree and IEEE802.1w Rapid Spanning Tree; IEEE802.1s Multiple Spanning Tree |
IPV6 Management |
Allow the user access by IPv4 or IPv6,And IPv6 supports the following features. IPv4/IPv6 Dual Protocol Stack Auto Configuration IPv6 Neighbor Discovery ICMPv6 SNMP over IPv6 HTTP/HTTPS over IPv6 TFTP over IPv6 Ping over IPv6 DHCPv6 |
Quality of Service |
The quality of service determined by port, Tag and IPv4 Type of service, IPv4 Different Service |
Class of Service |
Supports IEEE802.1p class of service, per port provides 4 priority queues |
Port Security |
Supports 100 entries of MAC address for static MAC and another 100 for MAC filter |
Port Mirror |
Supports 3 mirroring types: “RX, TX and Both packet” |
IGMP |
Supports IGMP snooping v1,v2 256 multicast groups and IGMP query |
IP Security |
Supports 10 IP addresses that have permission to access the switch management and to prevent unauthorized intruder. |
Login Security |
Supports IEEE802.1X Authentication/RADIUS |
Flow Control |
Supports Flow Control for Full-duplex and Back Pressure for Half-duplex |
System Log |
Supports System log record and remote system log server |
SNTP |
Supports SNTP to synchronize system clock to Internet |
Bandwidth Control |
Support ingress packet filter and egress packet limit The egress rate control supports all of packet type and the limit rates are 100K~102400Kbps(10/100), 100K~256000Kbps(1000) Ingress filter packet type combination rules are Broadcast/Multicast/Unknown Unicast packet, Broadcast/Multicast packet, Broadcast packet only and all of packet. The packet filter rate can be set from 100K~102400Kbps(10/100), 100K~256000Kbps(1000) |
Relay Alarm |
Provides one relay output for port breakdown, power fail alarm. Alarm Relay current carry ability: 1A @ DC24V |
SNMP Trap |
1. Cold start 2. Link down 3. Link up 4. Authorization fail |
DHCP |
Provides DHCP Client/ DHCP Server/ Port and IP Binding |
DNS |
Provide DNS client feature and support Primary and Secondary DNS server. |
Firmware Update |
Supports TFTP firmware update, TFTP backup and restore. |
Factory reset & Watchdog design |
Factory reset bottom can restore all setting back to factory default and Watchdog design to automatically reboot switch under certain circumstances |
*Future Release
**Optional
- ICES-3080-G
8 10/100/1000TX Managed Industrial Switch; -10°C to 60°C
- ICES-3080-GE
8 10/100/1000TX Managed Industrial Switch; -30°C to 70°C
DIN Rail Power
AD1048-24FS |
4VDC, 2A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 18 Watts at 75°C.) |
AD1024-24F | 24VDC, 1A, Wide AC Input, Convection Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 75°C, which means the output is 9 Watts at 75°C.) |
AD1240-48S |
48VDC, 5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |
AD1120-48F |
48VDC, 2.5A, Wide AC Input, Build-in fan Cooled, DIN Rail or Wall Mounted, RoHS, Operating Temp. -20°C~50°C (ambient, derating each output at 2.5% per degree from 50°C ~ 70°C) |